Induction Heating Case Hardening by Rotating

Image

Application: Case Harden Shaft by Rotating in Static Position
Original Concentrator: Silicon Steel Laminations
Problem / Failure Mode: Short Coil Life / Corrosion & Overheating of Laminations
Power Supply: 600 kW (450 kW in use), 3–10 kHz (9 kHz in Actual Use)

Problem / Solution:

  • Customer not satisfied with life of 150,000 cycles
  • Fluxtrol given opportunity to replace laminations
  • Application evaluated and Fluxtrol 50 chosen
  • No other changes were made other than Fluxtrol 50
  • Laminations removed and replaced with Fluxtrol 50
  • Tests meet spec and coil returned to production

Fluxtrol Advantage: Coil Life Extended to > 300,000 Cycles!

Read More